Show Solutions

Box Truss; Carts; Clamps/Couplers; Conversion Plates; Coupler Plates; Grip Bloks; Hinged Plates/Blocks; Lamp Bar Rolling Rack; Roof Systems; Side Support Arms; Support Bars; Top Truss Mounts; Truss Blocks; Truss Dollies; Truss Picks; Truss Spacers; Truss Scrim Covers; Wagon Wheels; Staging Products Duro Deck Stage Decks; Stage Deck Cases; Duro ....

Thickeners

36 in Dorr Oliver Thickener Head Size: 36 in diameter Comes with torque indicator Chain driven throu ID: 163720 Quote + Eimco 35 ft Thickener Bridge Type: BX thickener mechanism Bridge suppoer rake mechanism and W-60 26 rpm ID: 161554 Quote + Dorr-Oliver 24 ft Thickener 10 ft deep 24 ft diameter 9 ft 3 in discharge height...

How a Thickener Works

How a Thickener Works , The machine is so called because the thickening mechanism is driven by means of a traction wheel which travels around the periphery of the tank on a rail The mechanism, which is slowly carried around the tank as the traction wheel travels, consists of a truss to which are attached the raking blades which sweep the ....

Industrial Thickeners

Pioneers in the industry, we offer Sludge Thickener and Center Driven Thickener from India...

US1938894A

As an example of results attained in practice, with gluten, the present system has given a flnal density of 165 oz of solids per gallon with 185 hours detention, as against 138 oz per gal with 33 hours detention using the ordinary continuous thickening system; or 11 oz per gallon with 30 hours detention in the use of the customary batch ....

Raised Heel Options

Aug 31, 2017· Some truss manufacturers take that a step higher with a little stud under the top chord You can specify whatever height you need to But better roof framing is not confined to engineered truss...

Conventional Thickeners

In the column type a central steel or concrete column takes vertically the reaction to the weight of the mechanism and horizontally the torque load...

Conventional Thickeners

Basically there are two groups of thickeners which differ in their rake driving mechanisms: , the mechanism plus any solids that accumulate within the arms truss and horizontally to the twin forces imposed by the density of the raked underflow , to any operational load and serves merely as the inner support for the walkway To view the ....

Structural Support

Structural Support - Belmar, NJ Building Problem Solutions Professional Servic John F Mann, PE Structural engineer, structural design, building inspection, investigation of design and construction defects, home warranty claims We provide engineering services for home owners, home buyer, real estate firms, attorneys, contractors, architects, insurance companies, mortgage compani...

cascade

cascade-mfg-co...

Thickeners

Eimco 48 inch Type B Thickener Heads Type B 5 hp Gearhead motor Chain drive to thickener head Manual raise ID: 51386 Quote +; Thickener & Clarifier Drives...

ZXN Sludge Thickener | Dissolved ,

ZXN Sludge Thickener Send us inquiry By jorsun editor - 1123,2015 , steady flow tube, scraping truss, overflow device, center support, drive unit, skimming scraper and electric control panel , Mechanism: Scraping arm is rotated around the central axis of the clarifier by central drive units, a set of small scraper which ....

Cable supported rake arm thickener

Jun 14, 1988· BACKGROUND OF THE INVENTION 1 Field of the Invention This invention relates to cable supported and cable pulled raking arms for sedimentation thickeners, more particularly, the invention is directed to thickeners of the traction-type or center drive type, with a rake support and cabling system which eliminates the need for a thickener center structure capable of resisting large ,...

US Steel Truss

US Steel Truss - A Direct Source For Steel Truss and Components For Contractors & Private Labels Building Packages, Pole Barns, Garages, Steel Trusses, Barns...

Engineer needed for decorating trusses?

e) Trusses have been tested for 3D system effects that are unaccounted for in design and, as turns out, enhance performance substantially f) The truss guys use about the same levels of load that your average, wood friendly EOR would use in the same situation And they'll use whatever is specified if an EOR is involved in the project...